What are the common faults of Advantech industrial computer?
Published:2023-01-11 17:19:29
1. Maintenance of chip-level motherboard, dealing with crash, startup without flash, power-off and other problems, and providing BGA service;
2. Deal with the black screen and flower screen in the operation of the industrial computer, and correct the keyboard and LCD flash screen;
3. Replace all kinds of industrial computer accessories, such as LCD flash screen, CD drive movement, keyboard, etc.
4. Dust removal and protection inside the machine;
5. The operating system cannot be installed on the industrial computer.
6. Press the switch of the industrial computer, you can see the indicator light on, but the screen does not flash;
7. An English or digital error message appears on the startup screen of the industrial computer, and the system cannot be accessed;
8. The industrial computer does not recognize CD-ROM drive, hard disk, floppy drive, serial port, parallel port, network card port, etc.
9. Press the switch of the industrial computer, but there is no reaction (can not start);
10. Industrial computer often crashes, power off or restarts automatically;
11. The battery of the industrial computer cannot be charged;
12 industrial computer startup flash, but the screen is very dark, with the brightness function key debugging without any change;
13. The touch screen of the industrial computer is white (no text image) or flower screen, but the external flash is normal;
14. The touch screen of the industrial computer has horizontal or longitudinal bright lines and bright belts;
15. The startup screen of industrial computer is black, but the image of external flash device is normal.

-
202302-07WEINVIEW TK6070ih touch screen into the system setting what are the methods?
1. Generally, there is a small black arrow button in the lower right corner of the touch screen. After clicking and entering the correct password, you can enter the system Settings. However, during co···
-
202307-20How to disassemble the five or six axes of the Eston robot?
1. Open the shell of the robot to reveal the motor base.2. Use a screwdriver or wrench to remove the screws on the motor base.3. Remove the screw, lift the motor base, and remove it from the robot.4. ···
-
202302-21Omron plc equipment disassembly sequence and method
(1) Stop the machine for maintenance, and more than two people must monitor the operation;(2) Switch the mode selection switch on the front panel of CPU from "Run" to "Stop" positi···
-
202212-29This section describes how to set a gateway for Advantech switch eki-2528
step 1: Configure a VLAN. You are advised to allocate a dedicated VLAN, for example, VLAN 1000, for the management IP address of the switch on the network.Configuration command: vlan 1000step 2: Set a···
-
202302-17New features of Siemens SIMATIC S7-1200 PLC V2.0
In addition to the existing product features, SIMATIC S7-1200 V2.0 adds the following mechanisms and features:Integrated PROFINET-IO controller interface with integrated PROFINET interfaceProfibus DP ···

+8618621383628
+8613811814778
info@zhongpingtech.com
Building 26, Liyuan Community, Chaoyang District, Beijing, China