How does Delta inverter adjust the frequency?
Published:2023-02-27 16:23:10
Delta frequency converter, frequency adjustment is mainly operated in the control panel, process:
1. Press the Menu button to enter the parameter programming menu.
2, P0.01=1, input this parameter to complete the panel button correction frequency,;
3, P0.01=0, input this parameter can complete the panel to imitate the potentiometer correction frequency;
4. After correcting parameters, press ENTER button to acknowledge, and then press MENU button to exit to 0.00 frequency display condition.
5, use the panel button to correct the frequency, press the upward triangle button to increase the frequency.
** Low operating frequency: that is, the minimum speed of the motor operation. When the motor works at a low speed, its heat dissipation function is very poor. If the motor works at a low speed for a long time, the motor will be burned. And at low speeds, the current in the cable will increase, which will also lead to cable heating.
** High operating frequency: general frequency converter ** high frequency to 60Hz, and some even to 400 Hz, high frequency will make the motor high-speed operation, which for general motors, the bearing can not exceed the external speed operation for a long time, whether the rotor of the motor can accept such centrifugal force.
Carrier frequency: The higher the carrier frequency is set, the greater the weight of the higher harmonics, which is closely related to the length of the cable, motor heating, cable heating, frequency converter heating and other factors.

-
202302-20This section describes how to set the bios of Advantech mainboard
1. Set the system date and timeOn the standard BIOS setting screen, press arrow keys to move the cursor to Date and Time, and then press Page Up/Page Down or +/&S722 to correct the date and time o···
-
202302-06Does the supply cable between the Siemens soft starter and the motor need shielding
For 3RW soft starters, it is sufficient to use an unshielded main loop cable between the motor and the 3RW soft starter.The main reasons are as follows:The frequency of the power supply on the motor t···
-
202301-10Failure analysis of Mitsubishi Frequency Converter OC1 and OC3
Many times when Mitsubishi frequency converter presents OC (overcurrent problem), it is caused by the following reasons. Take A500 series frequency converter as an example:1) Caused by improper parame···
-
202302-22Principle of abb leakage switch
The operation principle of the leakage switch is: there are two groups on an iron core: An input current winding and an output current winding, when there is no leakage, input current and output curre···
-
202301-29The role of Schneider instrument in air separation process
The surface of the instrument plays an important role in the air separation equipment and the process of gas purification. It is essential for the adjustment of the air separation process and the dete···

+86 13811814778
+86 13811814778
Building 26, Liyuan Community, Chaoyang District, Beijing, China