What are the applications of CASAPPA synchronous motors?
Published:2023-08-31 15:54:45
1, as a flow distribution device, according to the system requirements to distribute the output flow of the pump
If the shaft is equipped with multiple sets of plain bearings, it is required to ensure that each bearing is supplied with the same amount of oil or in proportion. Synchronous shunt motors do not have any external leakage, and if one part of the rotor is rotating, the other parts will also pass through the same or proportional flow.
2, as a flow balancing device, synchronous operation of multiple cylinders or motors
If several motor live hydraulic cylinders work in parallel, supplied by the same oil source, and there is no control in any way on each branch, then the one bearing the smallest load starts the working cycle first, after its stroke is completed, the second smallest load starts working, and so on.
However, this mode of work is usually not the required mode, so the total pump flow is divided into a series of partial flow, so that several motors or hydraulic cylinders working in parallel are opened at the same time, and at the same time reach the designated position, and the synchronous shunt motor plays this important role.
3. As a booster device, the pressure of a certain output outlet of the shunt exceeds the output pressure of the pump
Synchronous shunt motor, in addition to being a "synchronous element", can also be used as a "supercharger", so that a certain output pressure of the motor exceeds the output pressure of the hydraulic pump.

-
202302-14What fault does ABB soft starter show EF32?
What is ABB soft starter fault codes EF32.The ABB PSE series soft start is a three-phase controller with a compact design and a wide range of applications.It is mostly used in water pump motors,and th···
-
202301-16TPC1561HI MCGS on-state touch screen operation panel common faults
TPC1561HI MCGS touch screen operation panel common faults(1) Black screen, flower screen and white screen(2) LCD screen aging, low high pressure, lamp aging(3) The LCD screen has no display, and the b···
-
202301-10Failure analysis of Mitsubishi Frequency Converter OC1 and OC3
Many times when Mitsubishi frequency converter presents OC (overcurrent problem), it is caused by the following reasons. Take A500 series frequency converter as an example:1) Caused by improper parame···
-
202302-10Parameter interpretation of Omron relay
Rated working voltage (current) :Also known as coil voltage, it refers to the voltage or current that the relay can work reliably. When the relay is working, the input voltage or current of the relay ···
-
202301-16TPC1262HI Common faults of MCGS on-state touch screen
TPC1262HI Common faults of MCGS touch screen(1) Black screen, flower screen and white screen(2) LCD screen aging, low high pressure, lamp aging(3) The LCD screen has no display, and the brightness is ···

+86 13811814778
+86 13811814778
Building 26, Liyuan Community, Chaoyang District, Beijing, China