What are the applications of CASAPPA synchronous motors?
Published:2023-08-31 15:54:45
1, as a flow distribution device, according to the system requirements to distribute the output flow of the pump
If the shaft is equipped with multiple sets of plain bearings, it is required to ensure that each bearing is supplied with the same amount of oil or in proportion. Synchronous shunt motors do not have any external leakage, and if one part of the rotor is rotating, the other parts will also pass through the same or proportional flow.
2, as a flow balancing device, synchronous operation of multiple cylinders or motors
If several motor live hydraulic cylinders work in parallel, supplied by the same oil source, and there is no control in any way on each branch, then the one bearing the smallest load starts the working cycle first, after its stroke is completed, the second smallest load starts working, and so on.
However, this mode of work is usually not the required mode, so the total pump flow is divided into a series of partial flow, so that several motors or hydraulic cylinders working in parallel are opened at the same time, and at the same time reach the designated position, and the synchronous shunt motor plays this important role.
3. As a booster device, the pressure of a certain output outlet of the shunt exceeds the output pressure of the pump
Synchronous shunt motor, in addition to being a "synchronous element", can also be used as a "supercharger", so that a certain output pressure of the motor exceeds the output pressure of the hydraulic pump.
-
202303-17
Installation guide for Siemens S7--200 equipment
The S7-200 can be mounted on a panel or standard guide rail. The S7-200 can be mounted horizontally or vertically.warningSIMATIC S7-200 PLC is an open controller. It requires the S7-200 to be installe···
-
202301-05
Siemens F7453 after the treatment measures
1. Cause F7453 occursWhen Epos function is used, a bearing ring encoder will be set. If the numerical feedback of the bearing ring encoder presents problems, F7453 problems will be reported, represent···
-
202302-23
The solution of Schneider inverter fault code
PHF: ⒈ Frequency converter power supply is not correct or fuse is blown; B. There is momentary defect in some phase. ⒈ Check the power supply connection and fuse; B. Reposition.USF: ⒈ Supply voltag···
-
202212-30
Nine main characteristics of Omron relays
1. Extremely small and lightweight typeOmron relay has developed and manufactured an extra small standard, the first relay profession at home and abroad, occupies a leading position in the market.2, l···
-
202302-16
Solution of MCGS communication problem
1. How to check the communication status of the device in Kunlun Mode (MVGS)In all MCGS non-board devices (except some custom devices), *** channels are communication channels. That is, after entering···