RKC Thermostat -What are the common faults of thermostat?
Published:2023-08-28 16:14:58
1, the power does not appear. This kind of problem first confirm whether the power supply is available and whether the power supply is matched with the power supply required by the thermostat, and then check whether the wiring is strong. The problem remains, then it is the problem of the thermostat itself.
2, there are manifestations, manipulation mistakes. This kind of problem should first look at the control wiring, and then consider the sensor and the actuator.
3, the temperature controller control temperature and practice temperature deviation. This kind of problem should be the PID parameter tuning problem, the need to set PID parameters from scratch.
4, heating for a period of time, the temperature has not changed, has been the ambient temperature. This kind of problem is actually a thermocouple problem, and its problem can easily lead to the temperature controller showing the ambient temperature.
5, the heating process, the temperature is getting lower and lower. There's a good chance the thermocouple's in reverse.
6, the temperature controller display and practice value is different. Such problems can be seen whether the wiring is loose, the sensor is damaged, and the type of sensor used does not match the type of sensor selected by the instrument.
-
202302-16
Mitsubishi 5U PLC and MCGS touch screen connection
First of all, let's look at the interface Settings of Kunlun touch screen.1. Click the device window to enter Add PLC2. Add a TCP parent serial port and add a 5U device below3. Double-click the pa···
-
202410-16
Enhance Efficiency with ABB Variable Frequency Drive
The key to enhancing plant performance lies in the variable frequency operation of ABB. You can rely on us.Main advantages of ABB variable frequency operation1.️ Energy efficiency reduces energy cost···
-
202212-29
Mitsubishi plc and computer communication setting method
Open the Mitsubishi plc programming software, menu "Online" -- >" transmission Settings "inside to select your connection method.1, first Mitsubishi plc and computer connection ···
-
202302-24
WEINVIEW touch screen common faults and maintenance
(1) The startup indicator is normal, but the display shows no signal input (black screen);(2) Press the on key, the host does not have any response (the indicator light is not bright, the host startup···
-
202302-24
WEINVIEW prompts the solution to the download mode error
1. Software editing - System Parameter setting -HMI attribute - Port number: 8000 Change, such as 9000;2. Call up the computer Task Manager -- end the process com_e30.exe;3. Restart the computer;4. Qu···