RKC Thermostat -What are the common faults of thermostat?
Published:2023-08-28 16:14:58
1, the power does not appear. This kind of problem first confirm whether the power supply is available and whether the power supply is matched with the power supply required by the thermostat, and then check whether the wiring is strong. The problem remains, then it is the problem of the thermostat itself.
2, there are manifestations, manipulation mistakes. This kind of problem should first look at the control wiring, and then consider the sensor and the actuator.
3, the temperature controller control temperature and practice temperature deviation. This kind of problem should be the PID parameter tuning problem, the need to set PID parameters from scratch.
4, heating for a period of time, the temperature has not changed, has been the ambient temperature. This kind of problem is actually a thermocouple problem, and its problem can easily lead to the temperature controller showing the ambient temperature.
5, the heating process, the temperature is getting lower and lower. There's a good chance the thermocouple's in reverse.
6, the temperature controller display and practice value is different. Such problems can be seen whether the wiring is loose, the sensor is damaged, and the type of sensor used does not match the type of sensor selected by the instrument.

-
202306-15Schneider soft starter fault alarm maintenance method
1, Question -F 05(frequency error) :This problem is because the soft starter presents a problem when processing the internal power signal, causing a power frequency error. This situation needs to cons···
-
202306-21Delta servo motor regular diagnosis and repair method
First, the motor temperature is too high or the smoke motor common failureReasons :1. The load is too large; 2. Two-phase operation; 3. Air duct obstruction; 4. The working temperature is too high; 5.···
-
202212-30What are the main items of Omron plc overhaul?
1. Check the power supply. Check whether the voltage change range at the power terminal is within the allowable ±10% range.2. Work environment. Focus on checking whether the temperature, humidity, vi···
-
202302-17959698 reasons for failure of Siemens 3RW44 soft starter
3RW44 Soft starter 95,96,98 is a comprehensive fault, what causes it to operate?95,96,98 reasons for failure of Siemens 3RW44 soft starter95,96,98 is the normally open normally closed integrated fault···
-
202301-12Delta PLC maintenance knowledge introduction
1. Delta PLC power-on running light is not on, ERROR flickers, the possible cause is: no program2. Delta PLC can not communicate with the computer, which may be: RS23 is bad3. If the power indicator o···



+8618621383628
+8613811814778
info@zhongpingtech.com
Building 26, Liyuan Community, Chaoyang District, Beijing, China