Siemens SINAMICS G120 modular inverter advantages
Published:2023-08-18 15:49:06
1. Modular design creates a high degree of flexibility to adapt to future requirements for drive solutions
The control unit can be replaced with power (hot swap)
Use plug terminals
The procedure for replacing the device is simple and easy to maintain
2. Safety features are integrated, so the cost of integrating the drive into the machinery or equipment with safety solutions is significantly reduced
3. Support PROFINET or PROFIBUS communication based on PROFIdrive Profile 4.0
Plant wide engineering design can be realized
Easy to handle
4. With innovative loop design (two-way input rectifier and "reduced capacity" DC bus), the kinetic energy of the load can be returned to the power supply system when using the power module PM250. Because of the feedback capability, there is no need to convert regenerative energy to heat through the brake resistance, resulting in a significant reduction in energy consumption.
5. Integrated USB interface, making local debugging and diagnosis easier
6. Integrated features for pump, fan and compressor applications, such as:
4 freely programmable PID controllers
Application-specific wizard
Equipped with Pt1000/LG-Ni1000 temperature sensor interface
AC 230 V relay
3 freely programmable digital timing switches
7. With CU250S-2 control unit: Integrated positioning function (basic locator EPos) can realize positioning tasks with high dynamic characteristics during operation. Positioning can be achieved by incremental encoders or/and ** value encoders (SSI)

-
202411-19what is plc?programmable logic controller meaning
In today's industrial production,PLC has become more and more important and common,but many people do not have a very clear understanding of it.Today,we will introduce PLC in detail from all aspec···
-
202302-03Reasons and solutions for the failure of Advantech Industrial computer
Advantech industrial computer can not open the machine may be industrial computer motherboard problemAdvantech industrial computer boot will self-check, to determine the condition of the machine, if t···
-
202301-12Delta PLC maintenance knowledge introduction
1. Delta PLC power-on running light is not on, ERROR flickers, the possible cause is: no program2. Delta PLC can not communicate with the computer, which may be: RS23 is bad3. If the power indicator o···
-
202302-23Schneider inverter commissioning procedure
1. Type recognition: Whether the type of frequency converter is common with the type of frequency converter purchased.2. Transportation admission: After opening the package, check whether the frequenc···
-
202306-15Schneider soft starter fault alarm maintenance method
1, Question -F 05(frequency error) :This problem is because the soft starter presents a problem when processing the internal power signal, causing a power frequency error. This situation needs to cons···

+86 13811814778
+86 13811814778
Building 26, Liyuan Community, Chaoyang District, Beijing, China