YOULI Multiway valve - Multiway valve regulation method
Published:2023-09-07 17:24:41
1. Under normal conditions, before the hydraulic multiway valve leaves the factory, its opening pressure should be adjusted one by one to the setting value required by the user. If the user puts forward the working pressure level of the spring, it should be adjusted according to the lower limit value of the pressure level.
2, before the user installs the multiway valve on the protected equipment or before installation, it must be adjusted at the installation site to ensure that the setting pressure value of the valve meets the requirements.
3. Within the range of the working pressure level of the spring indicated on the nameplate, the opening pressure can be adjusted by rotating the adjusting screw to change the compression of the spring.
4. Before rotating the adjusting screw, the valve inlet pressure should be reduced to less than 90% of the opening pressure to prevent the valve disc from being driven to rotate when rotating the adjusting screw, resulting in damage to the sealing surface.
5. In order to ensure the accuracy of the opening pressure value, the medium conditions, such as the type of medium and temperature, should be adjusted as close as possible to the actual operating conditions. When the type of medium changes, especially when the medium accumulates in a different state (for example, from a liquid phase to a gas phase), the opening pressure often changes. When the operating temperature rises, the opening pressure is generally reduced.
6, therefore, when adjusted at room temperature and used for high temperature, the setting pressure value at room temperature should be slightly higher than the required opening pressure value. The degree to which it is high is related to the valve structure and material selection, and should be based on the manufacturer's instructions.
7, basically all multi-way valves have a place to adjust the pressure, its nature is basically the same as the diesel pump, the valve itself is also a place to adjust the flow and pressure. Although there are a variety of valves, basically there will be a protruding screw on one side of the valve, a large nut on the outside and a hex screw on the inside.

-
202212-29Mitsubishi plc and computer communication setting method
Open the Mitsubishi plc programming software, menu "Online" -- >" transmission Settings "inside to select your connection method.1, first Mitsubishi plc and computer connection ···
-
202212-30What are the main items of Omron plc overhaul?
1. Check the power supply. Check whether the voltage change range at the power terminal is within the allowable ±10% range.2. Work environment. Focus on checking whether the temperature, humidity, vi···
-
202301-29Schneider frequency converter disturbance and treatment method
A. Communication method:(1) Radiation disturbance(2) conduction disturbanceB. Disturbance rejection methodNuisance signals transmitted by radiation methods are primarily weakened by wiring and by shie···
-
202301-30ABB frequency converter parameter setting method
1. GROUP99 Parameters: Apply macro to select standard macro, motor rating according to motor brand data, modify the set value.2. GROUP10 Parameter: Check whether parameter 1001 is 1. If no, set it to ···
-
202303-24How does the WEINVIEW touch screen connect with the Omron NJ controller?
First, Omron NJ controller programming1. Create the structure data type required by the project. For example, the Boolean switch quantity used in this example is combined to establish a structure data···

+86 13811814778
+86 13811814778
Building 26, Liyuan Community, Chaoyang District, Beijing, China