WEINVIEW prompts the solution to the download mode error
Published:2023-02-24 16:06:42
1. Software editing - System Parameter setting -HMI attribute - Port number: 8000 Change, such as 9000;
2. Call up the computer Task Manager -- end the process com_e30.exe;
3. Restart the computer;
4. Query other running programs that occupy port number 8000 on the computer through TCPview software and terminate or uninstall them. TCPview is a widget that you can use to view ports.
-
202302-23
The solution of Schneider inverter fault code
PHF: ⒈ Frequency converter power supply is not correct or fuse is blown; B. There is momentary defect in some phase. ⒈ Check the power supply connection and fuse; B. Reposition.USF: ⒈ Supply voltag···
-
202307-07
LS PLC use introduction
1, for switching quantity controlThe ability of PLC to control the switching quantity is very strong. The number of points controlled by the input and output points, as few as a dozen points, dozens o···
-
202301-06
Schneider isolation switch operation essentials
Schneider barrier switch features: First of all, Schneider barrier switch can be used to block the power supply, it can disconnect live equipment and high voltage maintenance equipment, but also can s···
-
202302-07
How do I set the IP address of the touch screen
How to set the IP address when the touch screen is in useFor example: CMT2109X2 and CMT2079XFirst - > Click the little yellow button on the touch screenNext - > Click the lock symbolAgain - >···
-
202303-08
How to choose Schneider Circuit Breaker?
First calculate the current value of each branchPure resistive load, such as light bulbs, electric heaters, etc., with the indicated power directly divided by the voltage, the formula I= power /220v; ···