Published:2023-05-05 11:07:30
After the frequency converter is used for more than half a year, if the equipment is to be run again, the chance of damage may be greatly increased because of the placing environment, the service life of the frequency converter, the load rate and other factors. The fault usually presents the following problems:
1. After the equipment is energized, the inverter explodes and the front circuit breaker jumps.
2. After startup, there is no display on the panel of frequency converter
3. The frequency converter operates normally after startup, but fails after operation
4. The frequency converter operates normally after startup, but it presents a blast machine after operation
Why does the above phenomenon of frequency converter failure occur?
1. Improper placing environment of frequency converter will lead to the above problems.
2. Frequency converter is composed of rectifier module, IGBT and electrolytic capacitor and other primary components. If the electrolytic capacitor is not energized for a long time, the electrolyte in the electrolytic capacitor will dry up, so that the capacity will decrease and the leakage will increase. In this way, when the converter is powered, the operation of the switching power supply will be abnormal or damaged. In serious cases, it will lead to the damage of the electrolytic capacitor of the main circuit, resulting in the blasting of the converter.
Why are some frequency converters still able to be used normally after being placed for a period of time?
1. Frequency converter storage environment is perfect
2. The frequency converter does not work in overheat or overload condition for a long time
3. The service life of frequency converter is short
4, the capacitor characteristics of the frequency converter is better than **
How to guard against frequency converter power-on failure?
1, Frequency converter is not used for a long time, should be sealed in a dust-proof and moisture-proof environment, storage temperature is -25c-65c.
2. It is safer and more useful to use special equipment to charge the inverter regularly (every 3 months) and check the input and output ports. The 220 volt voltage is supplied to the 380 volt converter (110 volts is supplied to the 220 volt converter), and the voltage slowly rises from 0 volts to 220 volts. The duration is determined by the power of the converter. Then, supply 380 volts (220 volts) to the converter and look at the input voltage. Only an imbalance of +/-3% is allowed.

-
202302-28Common fault problems of Omron relay
I. Do not exceed the rated voltage value of load current during the use of OMRON relay, because if the rated voltage is too high, it may cause local short circuit between coil cores of OMRON relay and···
-
202305-05Delta inverter long-term idle points for attention
After the frequency converter is used for more than half a year, if the equipment is to be run again, the chance of damage may be greatly increased because of the placing environment, the service life···
-
202212-29Siemens loads items into a memory card in transfer mode
Loads items to a memory card in transfer modeStep 1: Set the memory card to "transfer card" mode according to the above method. You are advised to clear all files from the memory card before···
-
202302-21Omron CP1 series PLC interrupt classification
1. Direct I/O interrupt is a change in the interrupt input from the built-in input unit on the CPU rack (0→1; 1→0).2, count interrupt, PLC CPU unit built-in input pulse count, count reach set value ···
-
202308-18Siemens SINAMICS G120 modular inverter advantages
1. Modular design creates a high degree of flexibility to adapt to future requirements for drive solutionsThe control unit can be replaced with power (hot swap)Use plug terminalsThe procedure for repl···



+8618621383628
+8613811814778
info@zhongpingtech.com
Building 26, Liyuan Community, Chaoyang District, Beijing, China