Maintenance points of Omron relay
Published:2023-02-01 15:32:10
1. The shell surface of the Omron relay used in installation should be free of scratches, cracks and damage. In case of serious damage, the intact relay with the same specifications should be replaced in time;
2. In the maintenance process of Omron relay, it is necessary to check whether the contact of Omron relay is broken or bright. If abnormal situation is found, maintenance personnel should timely deal with it;
3. Carefully check whether there are foreign bodies such as welding slag and dust inside the Omron relay to avoid affecting the performance of the relay;
Four. Check whether the coil inside the Omron relay is broken, but also check whether all the connections are broken, whether the solder joint is full and wet;
5. Because the pin of relay is easy to be damaged, it is necessary to check regularly whether the pin of Omron relay has deformation, discoloration or other mechanical damage;
Vi. Check whether the fastener of Omron relay is loose. If the above phenomenon is found, the maintenance personnel should tighten it in time;
Vii. In the actual use of Omron relay, the locating pin and the base may loosen under certain circumstances, so it is necessary to check whether the locating pin and the base are consistent and whether they are loose. In the process of inspection, if loose phenomenon is found, corresponding measures should be taken in time.
-
202307-27
Siemens S7-200 SMART Common questions about serial communication
1. Does the S7-200 SMART support Modbus ASCII communication mode?STEP 7- The Micro/WIN SMART software does not provide the Modbus ASCII communication mode instruction library. If the S7-200 SMART CPU ···
-
202302-07
How do I set the IP address of the touch screen
How to set the IP address when the touch screen is in useFor example: CMT2109X2 and CMT2079XFirst - > Click the little yellow button on the touch screenNext - > Click the lock symbolAgain - >···
-
202301-30
ABB frequency converter fault code
1. ABB inverter fault code: 0001Cause: The output current exceeds the trip valueMeasures: Check motor load, check acceleration time, check motor and motor cable (including phase sequence).2. ABB inver···
-
202212-30
What are the PLC characteristics of ABB?
1, high reliability, strong anti-interference abilityHigh reliability, strong anti-interference ability is one of the most important characteristics of PLC. The average trouble-free time of PLC can re···
-
202303-02
Mitsubishi servo motors one-button adjustment function
When different servo motors are installed on the machine for the first time, they will occasionally show a poor match with the machinery during operation, which will lead to vibration, noise and other···